Upravit stránku

Use of MODACT MOK electric actuators in combination with flaps

Flap DN [mm]PN [MPa]Torque of fitting [Nm]ActuatorType number [V]VoltageProtective enclosure IPResetting time for 90° [s]Flange
500,3
0,6
1,0
1,6
20
25
30
30

MOK 63

MOK 63

230
(400) *)

65

10, 20, 40, 80

F04, F05, F07
650,3
0,6
1,0
1,6
22
24
35
36

MOK 63

MOK 63

230
(400) *)

65

10, 20, 40, 80

F04, F05, F07
800,3
0,6
1,0
1,6
32
34
45
45

MOK 63

MOK 63

230
(400) *)

65

  20, 40, 80

F04, F05, F07
1000,3
0,6
32
50
MOK 6352 325
230
(400) *)

65
20, 40, 80F04, F05, F07
1,0
1,6
65
68
MOK 12552 32610, 20, 40, 80F05, F07, F10
1250,3
0,6
1,0
1,6
70
75
92
98

MOK 125

52 326

230
(400) *)

65

10, 20, 40, 80

F05, F07, F10
1500,3
0,6
95
110
MOK 12552 326
230
(400) *)

65
10, 20, 40, 80F05, F07, F10
1,0
1,6
140
150
MOK 25052 32720, 40, 80, 160F07, F10
2000,3
1,0
1,0
185
240
240
MOK 25052 327230
(400) *)

65
20, 40, 80, 160F07, F10
1,6265MOK 50052 32840020, 40, 80F10, F12
2500,3
0,6
1,0
1,6
300
340
370
425

MOK 500

52 328

400

65

20, 40, 80

F10, F12
3000,3
0,6
420
480
MOK 50052 328
400

65
20, 40, 80F10, F12
1,0
1,6
530
660
MOK 100052 32940, 80, 160F12
3500,3
0,6
1,0
1,6
600
660
770
880

MOK 1000

52 329

400

65

40, 80, 160

F12
4000,3
0,6
800
900
MOK 100052 329
400

65
40, 80, 160F12
1,0
1,6
 MO +
Mastergear
   

500
and higher

Combinations of M-G gear box and MODACT ® MOD actuator, protective enclosure IP 55,
motor 3x230/400 V (3x220/380V).

 

FLAPS (For control of these flaps, MODACT ® MOK single-turn actuators are used)

Type of fittingDN [mm]PN [MPa]Temperature max. [°C]Medium (application)ManufacturerMaterial
L 32 175-61650, 65
80, 100
125
150
1,6
1,5
1,4
1,2
120
(100)
water, (oils)JMA Hodoningrey cast iron, 
flap of brass,
rubber bush
L 32 175-610200-2501,0120
(100)
CV 8, 1050-12000,3-1,680
130
water, air, 
aggressive substances
Con Vey (GER)customer's requirements 
and the type of medium
BURACCO50-3000,6-1,6130water, air, 
aggressive substances
Buracco (GER)customer's requirements
 and the type of medium
Uranie50-10001,0-1,6do 130water, air, 
aggressive substances
Oreg (France)customer's requirements 
and the type of medium
Nahoru